P OW E R D I S T R I B U T I O N
8498
8598
8499
8599
8467
8567
Style
Traditional Metal
Traditional Metal
Traditional Metal
Total Positions
3 Sources + Transfer
2 Sources + 4 positions
2 Sources + 4 positions
A-Series
Circuit Breakers (PN)
2 Main, 30A (7238)
1 Main, 50A (7242)
1 Transfer, 30A (7238)
2 Main, 16A (7294)
1 Main, 32A (7295)
1 Transfer, 16A (7294)
2 Main, 30A (7238)
2 Branch, 15A (7210)
2 Main, 16A (7294)
2 Branch, 8A (7299)
2 Main, 30A (7238)
2 Branch, 15A (7210)
2 Main, 16A (7294)
2 Branch, 8A (7299)
Nominal Voltage
120V AC
230V AC
120V AC
230V AC
120V AC
230V AC
Actuator Style
White Toggle
White Toggle
White Toggle
Insulating Back Cover
-
-
4027 sold separately (p. 128)
Width x Height in (mm)
10.50 (266.70) x 4.50 (114.30)
10.50 (266.70) x 4.50 (114.30)
5.25 (133.35) x 7.50 (190.50)
Depth in (mm)
3.00 (76.20)
3.00 (76.20)
3.00 (76.20)
8489
8589
8462
8562
8466
8566
Style
Traditional Metal
Traditional Metal
Traditional Metal
Total Positions
2 Sources + 6 positions
2 Sources + 9 positions
2 Sources + 9 positions
A-Series
Circuit Breakers (PN)
2 Main, 30A (7238)
3 Branch, 15A (7210)
2 Main, 16A (7294)
3 Branch, 8A (7299)
2 Main, 30A (7238)
6 Branch, 15A (7210)
2 Main, 16A (7294)
6 Branch, 8A (7299)
2 Main, 30A (7238)
6 Branch, 15A (7210)
2 Main, 16A (7294)
6 Branch, 8A (7299)
Nominal Voltage
120V AC
230V AC
120V AC
230V AC
120V AC
230V AC
Actuator Style
White Toggle
White Toggle
White Toggle
Meter
0–150V (9353)
0–250V (9354)
0–150V (9353)
0–250V (9354)
-
Insulating Back Cover
-
-
-
Width x Height in (mm)
5.25 (133.35) x 11.25 (285.75)
10.50 (266.70) x 7.50 (190.50)
5.25 (133.35) x 11.25 (285.75)
Depth in (mm)
3.00 (76.20)
3.00 (76.20)
3.00 (76.20)
1208
1209
1231
1232
8032
8132
8061
8161
Style
360 Panel System
360 Panel System
Traditional Metal
Traditional Metal
Total Positions
2 Sources
2 Sources
2 Sources
2 Sources
A-Series
Circuit Breakers (PN)
2 Main, 30A (7574)
2 Main, 16A (7572)
2 Main, 50A (7577) 2 Main, 32A (7575) 2 Main, 30A (7238) 2 Main, 16A (7294) 2 Main, 50A (7242)
2 Main, 32A (7295)
Nominal Voltage
120V AC
230V AC
120V AC
230V AC
120V AC
230V AC
120V AC
230V AC
Actuator Style
Raised Rocker
Raised Rocker
White Toggle
White Toggle
Insulating Back Cover
1331 sold separately (p. 127)
1331 sold separately (p. 127)
4026 sold separately (p. 128)
4026 sold separately (p. 128)
Width x Height in (mm)
4.88 (123.83) x 4.75 (120.65)
4.88 (123.83) x 4.75 (120.65)
5.25 (133.35) x 3.00 (76.20)
5.25 (133.35) x 3.00 (76.20)
Depth in (mm)
3.00 (76.20)
3.00 (76.20)
3.00 (76.20)
3.00 (76.20)
AC Source Selection Circuit Breaker Panels
AC Source Selection panels allow the boater to select between two or three AC sources to supply power to the AC Branch distribution system
230 Volt (typical of Europe)
Component References
•
A-Series Circuit Breakers (p. 58-59)
•
AC Analog Meters (p. 120-121)
•
AC Digital Multimeter (p. 118-119)
•
Red reverse polarity indication LED (p. 128)
•
Green ON indicating LEDs (p. 128)
Features
•
Lockout slides ensure that no two sources of
AC power are connected to the circuit simultaneously
•
Backlit label positions
•
Traditional Metal panels with Branch circuit breakers
include PN 8031 label set (p. 129)
•
360 Panel System panels with Branch circuit breakers
include PN 4206 label set (p. 129)
•
All Panels include a Reverse Polarity label and a
Source Selection label set (p. 129)