98
Specifications subject to change. See bluesea.com for current information.
P OW E R D I S T R I B U T I O N
1206
1207
8043
8143
8409
8509
8405
8505
Style
360 Panel System
Traditional Metal
Traditional Metal
Traditional Metal
Total Positions
Main + 2 positions
Main + 3 positions
Main + 3 positions
Main + 3 positions
A-Series
Circuit Breakers (PN)
Main, 30A (7414)
2 Branch, 15A (7403)
Main, 16A (7412)
2 Branch, 8A (7401)
Main, 30A (7238)
3 Branch, 15A (7210)
Main, 16A (7294)
3 Branch, 8A (7299)
Main, 30A (7238)
3 Branch, 15A (7210)
Main, 16A (7294)
3 Branch, 8A (7299)
Main, 30A (7238)
3 Branch, 15A
(7210)
Main, 16A (7294)
3 Branch, 8A (7299)
Nominal Voltage
120V AC
230V AC
120V AC
230V AC
120V AC
230V AC
120V AC
230V AC
Actuator Style
Flat Rocker
White Toggle
White Toggle
White Toggle
Meter (PN)
0–150V (9353)
0–250V (8245)
0–150V (9353)
0–250V (8245)
0–150V (8244)
0–50A (8246)
0–250V (8245)
0–50A (8246)
Digital Multimeter (8247)
Insulating Back Cover
1341 sold separately (p. 127)
4027 sold separately (p. 128)
4027 sold separately (p. 128)
4027 sold separately (p. 128)
Width x Height in (mm)
4.88 (123.83) x 7.75 (196.85)
5.25 (133.35) x 7.50 (190.50)
5.25 (133.35) x 7.50 (190.50)
5.25 (133.35) x 7.50 (190.50)
Depth in (mm)
3.00 (76.20)
2.50 (63.50)
3.00 (76.20)
4.00 (101.60)
8077 †
8177 †
8079 †
8179 †
8029
8129
1214
1215
Style
Traditional Metal
Traditional Metal
Traditional Metal
360 Panel System
Total Positions
Main Only
Main Only
Main + 1 position
Main + 2 positions
A-Series
Circuit Breakers (PN)
Main, 30A
(7238)
Main, 16A
(7294)
Main, 50A
(7242)
Main, 32A
(7295)
Main, 30A
(7238)
Main, 16A
(7294)
Main, 30A (7414)
2 Branch, 15A (7403)
Main, 16A (7412)
2 Branch, 8A (7401)
Nominal Voltage
120V AC
230V AC
120V AC
230V AC
120V AC
230V AC
120V AC
230V AC
Actuator Style
White Toggle
White Toggle
White Toggle
Flat Rocker
Insulating Back Cover
-
-
4026 sold separately (p. 128)
1331 sold separately (p. 127)
Width x Height in (mm)
2.63 (66.80) x 3.75 (95.25)
2.63 (66.80) x 3.75 (95.25)
5.25 (133.35) x 3.75 (95.25)
4.88 (123.83) x 4.75 (120.65)
Depth in (mm)
2.50 (63.50)
2.50 (63.50)
2.50 (63.50)
3.00 (76.20)
AC Main Circuit Breaker Panels
The AC Main power system provides a path for delivering power from the ship’s source of AC power to the AC branch distribution system.
It begins at the AC power source (shore power, genset, or inverter), and ends at the AC branch circuit. See page 127 for a discussion of
ABYC ELCI recommendations for AC Main circuit protection.
230 Volt (typical of Europe)
8099
8199
8027
8127
8412
8512
1230
1233
Style
Traditional Metal
Traditional Metal
Traditional Metal
360 Panel System
Total Positions
Main + 4 positions
Main + 6 positions
Main + 6 positions
Main + 6 positions
A-Series
Circuit Breakers (PN)
Main, 30A (7238)
4 Branch, 15A (7210)
Main, 16A (7294)
4 Branch, 8A (7299)
Main, 30A (7238)
3 Branch, 15A (7210)
Main, 16A (7294)
3 Branch, 8A (7299)
Main, 30A (7238)
4 Branch, 15A (7210)
Main, 16A (7294)
4 Branch, 8A (7299)
Main, 30A (7414)
6 Branch, 15A
(7403)
Main, 16A (7412)
6 Branch, 8A (7401)
Nominal Voltage
120V AC
230V AC
120V AC
230V AC
120V AC
230V AC
120V AC
230V AC
Actuator Style
White Toggle
White Toggle
White Toggle
Flat Rocker
Insulating Back Cover
-
4027 sold separately (p. 128)
-
2 x 1331 sold separately (p. 127)
Width x Height in (mm)
10.50 (266.70) x 3.75 (95.25)
5.25 (133.35) x 7.50 (190.50)
10.50 (266.70) x 4.50 (114.30)
9.25 (234.95) x 4.75 (120.65)
Depth in (mm)
2.50 (63.50)
2.50 (63.50)
2.50 (63.50)
3.00 (76.20)
Component References
•
A-Series Circuit Breakers (p. 58-59)
•
AC Analog Meters (p. 120-121)
•
AC Digital Multimeter (p. 118-119)
•
Red reverse polarity indication LED (p. 128)
•
Green ON indicating LEDs (p. 128)
Features
•
Red reverse polarity indication LED
•
Green ON indicating LEDs
•
Backlit label positions
†
Panels without backlit labels
•
Traditional Metal panels include PN 8031 label set (p. 129)
•
360 Panel System includes PN 4206 label set (p. 129)
•
Source Selection Label Set included with panels
8077, 8177, 8079, and 8179 (p. 129)