M E T E R I N G
123
Specifications subject to change. See bluesea.com for current information.
1023B
1028B
2 Inch Round Gauges
Provides monitoring of key functions required for boat operation
Gauges are offered for use in 360 Panels
and are not available for retail purchase.
•
Watertight, fog resistant, and anti-scratch glass face
•
Edge-lit
•
Will fit panels up to 0.8" thickness
Specifications
Voltage Max. Operating
See table
Temperature Max. Operating
158°F (70°C)
Temperature Min. Operating
-4°F (-20°C)
Amperage Operating Current
(with edge-light)
180mA
Amperage Operating Current
(no edge-light)
<100mA
Gauge diameter
2.00" (50.80 mm)
Mounting hole diameter
2.06" (52.40 mm)
Back clamp nuts torque
5–7 in-lb
Regulatory
E
Marked
1030B
1027B
1026B
(gauge is not edge-lit)
1024B
1022B
1029B
Gauge Panel
For mounting 2 Inch Round Gauges
Small Format Label Sets
- 8214 and 8217 (p. 129)
1510
(Gauge not included)
PN
Width
in (mm)
Height
in (mm)
Depth
in (mm)
1510 4.88 (123.83) 4.75 (120.65) 0.50 (12.70)
PN
Function
Voltage Max. Operating
Depth in (mm)
1020B Fuel Level E–1/2–F
16V DC
1.75 (44.45)
1021B Potable Water Level E–1/2–F
16V DC
1.75 (44.45)
1022B Engine Temp 100–250°F
16V DC
1.75 (44.45)
1023B Oil Pressure 0–80 PSI/Bar
16V DC
1.75 (44.45)
1024B Water Pressure 0–30 PSI/kPa
16V DC
2.10 (53.54)
1025B Voltmeter 10–16 Volts
16V DC
1.75 (44.45)
1026B Hour Meter—10,000 hrs
32V DC
2.40 (60.96)
1027B Battery Condition Indicator
16V DC
3.00 (76.20)
1028B DC Ammeter 60–0–60 Amps
16V DC
1.75 (44.45)
1029B Clock—Quartz Analog
16V DC
2.70 (68.58)
1030B Tank Level
16V DC
1.75 (44.45)
DC Shunts
Use with DC Ammeters (p. 116, 118, 120)
PN For Use With
Ratio
9228 Analog Ammeter
50A DC/50mV DC
9230 Analog Ammeter
100A DC/50mV DC
9233 Analog Ammeter
200A DC/50mV DC
8255
Digital Ammeter,
VSM 422
500A DC/50mV DC
9228
9233
8255
AC Current Transformers
Use with AC Ammeters
Specifications
8073 Dimensions 0.60 in (15.24 mm) Inside Diameter
1.38 in (35.05 mm) Outside Diameter
1829 Dimensions 1.25 in (31.75 mm) Inside Diameter
2.68 in (68.2 mm) Outside Diameter
8073
PN
For Use With
Ratio
8073 Analog Ammeter
50A AC/50mA AC
8257 Analog Ammeter
100A AC/50mA AC
8256 Digital and M2 Ammeter
150A AC/50mA AC
1829 M2 Ammeter and M2 Multimeter
300A AC/50mA AC
•
For continuous operation, it is recommended that
shunts not be run at more than two-thirds (66%)
the rated current under normal conditions
Specifications
Shunt Type
Resistive
Full Scale
50 mV
Amperage Max. Operating
66% of Rated Current
Amperage Int. Rating (5 min.)
100%—Full scale rating
Amperage Int. Rating (3 sec.)
300%—Full scale rating
Related Products
Analog Meters
p. 120-121
2719 Enclosure
p. 76
DIN Meters
p. 120-121
Digital Meters
p. 118-119
VSM 422
p. 115
1829
M2 OLED
Digital Monitors
p. 116-117