M E T E R I N G
121
Specifications subject to change. See bluesea.com for current information.
AC Analog Meters
Micro and Standard and DIN meters with backlighting for low light conditions
•
Includes appropriate external transformer (p. 123) when required
•
Backlit meter face (separate 12 or 24V DC backlight connections)
•
DIN Meters include a terminal cover included to prevent accidental short circuit
•
DIN Meters are a standard European 72mm design
•
DIN Meter face is white matte with black printed scale and knife-edge pointer
Standard Meter
2.375"
60.33mm
2.625"
66.68mm
0.401"
10.19mm
0.800"
20.32mm
2.27"
57.66mm
2.80"
71.12mm
0.226"
5.74mm
1.26"
32.00mm
.30" DIA. 7.62mm
adjustment hole
Panel Mount
Surface Mount
Micro Meter
2.00"
50.80mm
.25" DIA. 6.35mm
adjustment hole
1.86"
47.24mm
1.055"
26.80mm
0.455"
11.56mm
1.58"
40.13mm
2.00"
50.80mm
0.90"
22.86mm
0.87"
22.10mm
0.105"
2.67mm
0.625" MAX.
15.88mm
0.45" (11.43mm) - Standard Meter
0.40" (10.16mm) - Micro Meter
0.95" (24.13mm) - Standard Meter
0.85" (21.59mm) - Micro Meter
0.125" (3.18mm)
Screw
PN
Function
Operating Amperage (Meter)
Operating Amperage (Backlight)
Connection
8244
Micro Voltmeter 0–150V AC 1 mA at full scale
16 mA@12V DC, 20 mA@24V DC 2 wire to AC hot and neutral, 3 connections for backlight
8245
Micro Voltmeter 0–250V AC 1 mA at full scale
16 mA@12V DC, 20 mA@24V DC 2 wire to AC hot and neutral, 3 connections for backlight
9353
Standard Voltmeter 0–150V AC 1 mA at full scale
16 mA@12V DC, 20 mA@24V DC 2 wire to AC hot and neutral, 3 connections for backlight
9354
Standard Voltmeter 0–250V AC 1 mA at full scale
16 mA@12V DC, 20 mA@24V DC 2 wire to AC hot and neutral, 3 connections for backlight
1056
DIN Voltmeter 0–150V AC
1 mA at full scale
16 mA@12V DC, 20 mA@24V DC 2 wire to AC hot and neutral, 3 connections for backlight
1057
DIN Voltmeter 0–250V AC
1 mA at full scale
16 mA@12V DC, 20 mA@24V DC 2 wire to AC hot and neutral, 3 connections for backlight
PN
Function
Operating Amperage (Meter)
Operating Amperage (Backlight)
Connection
8246
Micro Ammeter 0–50A AC
50 mA at full scale
16 mA@12V DC, 20 mA@24V DC 2 wire from coil slipped over wire to be measured, 3 connections for backlight
9630
Standard Ammeter 0–50A AC 50 mA at full scale
16 mA@12V DC, 20 mA@24V DC 2 wire from coil slipped over wire to be measured, 3 connections for backlight
8258
Standard Ammeter 0–100A AC 50 mA at full scale
16 mA@12V DC, 20 mA@24V DC 2 wire from coil slipped over wire to be measured, 3 connections for backlight
1058
DIN Ammeter 0–50A
50 mA at full scale
16 mA@12V DC, 20 mA@24V DC 2 wire from coil slipped over wire to be measured, 3 connections for backlight
9353
8244
9630
8246
TERMINAL
COVER
0.236"
6.00mm
1.456"
37.00mm
0.551"
14.00mm
2.835"
72.00mm
2.598"
66.00mm
0.787"
20.00mm
2.835"
72.00mm
1056
1058
DIN Meter