M E T E R I N G

117

Specifications subject to change. See bluesea.com for current information.

360 Panel mount

Rear mount

Surface mount

1836

AC Ammeter

Monitors AC Amperage on large, bright display.

Supports programmable current transformer ratios.

Accurately measure and alarm the amperage of your AC

system. (measures 2 independent circuits)

Current Measurement

Range

300A

Range 1 (Resolution 0.1A) 0.00-29.9A AC (RMS)

Range 2 (Resolution 1A) 30-150A AC (RMS)

Alarms/Relay

High/Low Current

1837

AC Voltmeter

Monitors AC Voltage on large, bright display.

Accurately measure and monitors the voltage of your AC system.

(measures 2 independent circuits or 1 double phase circuit)

Voltage Measurement

Range

50-250V AC*

Resolution

1V AC

Alarms/Relay

High/Low Voltage

1838

AC Multimeter

Monitors AC Amps, Volts, Hzs on large, bright display.

Supports programmable current transformer ratios.

Accurately measure and monitor AC amperage,

voltage and Hz. (measures 2 voltages and 2 circuits)

Voltage Measurement

Range

50-250V AC*

Resolution

1V AC

Current Measurement

Range

300A

Range 1 (Resolution 0.1A)

0.00-29.9A AC (RMS)

Range 2 (Resolution 1A)

30-150A AC (RMS)

Frequency Measurement

Range

40-90Hz

Resolution

1 Hz

Power Measurement

Range 1 (Resolution 10W)

0-9990W

Range 2 (Resolution 0.1kW)

10-45kW

Included Current Transformer

8256 (page 123)

Alarms/Relay

High/Low Voltage

High/Low Current

High/Low Frequency

AC M2 OLED Digital Monitors

The M2 OLED Digital Monitor measures essential electrical system parameters with

adjustable alarms and an auto-dimming display in a compact enclosure. The gasket creates a

waterproof seal on the unit face. The M2 Monitors include a MOSFET External Circuit Relay (ECR)

which can be used to control external circuits based on any value measured by the M2. The M2

External Circuit Relay is separate from and independent of the Internal Alarm function.

Auto-dimming, bright OLED display is easy to read

Easy to adjust

92dB alarm on all models

Isolated MOSFET relay

PN

Description

Measurement

Included Transformer

1836 AC Ammeter

Amperage

150A PN 8256 (p. 123)

1837 AC Voltmeter

Voltage

-

1838 AC Multimeter

Voltage,Current,Frequency

150A PN 8256 (p. 123)

Regulatory

Unit face is IP67—Protected against immersion up to 1 meter for 30 minutes

Surface Mount Gasket creates a waterproof seal on unit face

CE marked for E60945 electromagnetic interference

* Variable with voltage, display intensity, segments illuminated, and sleep mode

† 150A with included transformer, 300A with PN 1829 transformer (p. 123)

Specifications

Display Size

55mm x 28mm

Power Supply Voltage

7-70V DC

Max. Power Consumption

1.00W*

Min. Power Consumption

0.3W*

Scan for

additional

product

information

Related Products

ML-Series Solenoid

p. 23

Floyd Bell Turbo Series Alarm