92

Specifications subject to change. See bluesea.com for current information.

P OW E R D I S T R I B U T I O N

8025

1216

1455 †

1459 †

8081

Style

Traditional Metal

360 Panel System

360 Panel System

360 Panel System

Traditional Metal

Total Positions

3 Positions

4 Positions

4 Positions

4 Positions

5 Positions

Circuit Breakers (PN)

3 A-Series, 15A (7210)

4 A-Series, 15A (7403)

4 Push Button, 10A (7054)

4 Push Button, 10A (7054)

5 A-Series, 15A (7210)

Rocker Switches (PN)

4 ON-OFF, SPST (7480)

4 ON-OFF, SPST (7480)

Nominal Voltage

12/24V DC

12V DC

12V DC

12V DC

12V DC

Maximum Amperage

100A

100A

40A

40A

50A

Meter (PN)

8–16V (8003)

8–16V (8028) / 0–50A (8041)

Width x Height in (mm)

5.25 (133.35) x 4.75 (120.65)

4.88 (123.83) x 4.75 (120.65)

4.88 (123.83) x 4.75 (120.65)

4.88 (123.83) x 7.75 (196.85)

5.25 (133.35) x 7.50 (190.50)

Depth in (mm)

2.50 (63.50)

3.00 (76.20)

3.50 (88.90)

3.50 (88.90)

2.50 (63.50)

1200

1225

8023

8385

1463 †

Style

360 Panel System

360 Panel System

Traditional Metal

Traditional Metal

360 Panel System

Total Positions

8 Positions

8 Positions

8 Positions

8 Positions

8 Positions

Circuit Breakers (PN)

8 A-Series, 15A (7403)

8 A-Series, 15A (7403)

5 A-Series, 15A (7210)

6 A-Series, 15A (7210)

8 Push Button, 10A (7054)

Rocker Switches (PN)

8 ON-OFF, SPST (7480)

Nominal Voltage

12V DC

12V DC

12/24V DC

12/24V DC

12V DC

Maximum Amperage

100A

100A per bus

100A

100A per bus

80A

Meter (PN)

8–16V (8003)

Width x Height in (mm)

4.88 (123.83) x 7.75 (196.85)

9.25 (234.95) x 4.75 (120.65)

5.25 (133.35) x 7.50 (190.50)

10.50 (266.70) x 4.50 (114.30)

4.88 (123.83) x 10.75 (273.05)

Depth in (mm)

3.00 (76.20)

3.00 (76.20)

2.50 (63.50)

2.50 (63.50)

3.50 (88.90)

DC Branch Circuit Breaker Panels

DC Branch panels distribute current from a high amperage input into lower amperage circuits

Without ON-indicating LEDs or backlit label positions

8401

8096

1450 †

1457 †

1456 †

Style

Traditional Metal

Traditional Metal

360 Panel System

360 Panel System

360 Panel System

Total Positions

5 Positions

6 Positions

8 Positions

8 Positions

8 Positions

Circuit Breakers (PN)

5 A-Series, 15A (7210)

6 A-Series, 15A (7210)

8 Push Button, 15A (7056)

8 Push Button, 10A (7054)

8 Push Button, 10A (7054)

Rocker Switches (PN)

8 ON-OFF, SPST (7480)

8 ON-OFF, SPST (7480)

Nominal Voltage

12/24V DC

12/24V DC

12/24V DC

12V DC

12V DC

Maximum Amperage

100A

100A per bus

90A

80A

80A

Meter (PN)

Digital Multimeter (8248)

Width x Height in (mm)

5.25 (133.35) x 7.50 (190.50)

10.50 (266.70) x 3.75 (95.25)

4.88 (123.83) x 4.75 (120.65) 4.88 (123.83) x 7.75 (196.85)

9.25 (234.95) x 4.75 (120.65)

Depth in (mm)

4.00 (101.6)

2.50 (63.50)

3.50 (88.90)

3.50 (88.90)

3.50 (88.90)

Component References:

A-Series Circuit Breakers (p. 58-59)

Push Button Reset-Only Circuit Breakers (p. 53)

ON-OFF, SPST Rocker Switches (p. 69)

360 Panel System includes PN 4205 label set (p. 129)

Traditional Metal panels include PN 8030 label set (p. 129)

Features:

ON-indicating LEDs for select models †

Backlit label positions for select models †

Panels with voltmeters include a toggle

switch to monitor voltage on up to three

battery banks

DC Digital Multimeter (p. 118-119)

DC Analog Meters (p. 120-121)

Amber ON-indicating LEDs (p. 128)