27
Specifications subject to change. See bluesea.com for current information.
B AT T E R Y M A N A G E M E N T
Selection Chart
Choose the right Remote Battery
Switch for your application
PN
7700
7700100B
7702
7702100B
7713
7713100B
7717
7717100B
Application
Battery switching from a convenient location
with Multi-Station control capability
and no continuous current draw
Battery switching from a convenient location
with Master ON-OFF control of individually
switched units
Manual Control Override Knob
Provides an added level of safety allowing control with or without power, and
offering LOCKED OFF capability for security and servicing
Nominal Voltage
12V DC
24V DC
12V DC
24V DC
Contact Circuit Voltage
32V DC Max.
32V DC Max.
16V DC Max.
32V DC Max.
Control Wires
2 wires connect battery switch to remote
switch: one to open and one to close relay
1 wire connects battery switch to remote switch
Control Current
Positive pulsed once to change relay state
Positive continuous current to close
Amperage Operating Current - continuous
@ 25°C nominal VDC
0mA
< 13mA
Amperage Operating Current - when changing state
< 7.0A DC
< 4.0A DC
< 7.0A DC
< 4.0A DC
Coil Function
Magnetic Latching Bi-Stable
Magnetic Latching Auto-Releasing
Control Switch Included
2145 SPDT (ON)-OFF-(ON)
2155 SPDT ON-ON
Multi-Station Switching Capability
Yes
–
Master Control Switch Capability
–
Yes
Wire Color
7700, 7700100B
7702, 7702100B
Circuit Function
7713, 7713100B
7717, 7717100B
Circuit Function
Red
+V DC, 24 Hour
Control +V DC, To Close
Black
Ground
Ground
Yellow
- V DC LED Output
- V DC LED Output
Brown
+V DC, To Close
--
Orange
+V DC, To Open
--
3.0" 76.20mm
5.47"
138.94mm
4.50"
114.30mm
3.75" 95.25mm
2.03"
51.56mm
1.90"
48.26mm
1.03"
26.16mm
Wire Harness Connections
Everglades uses a combination of 7620 Automatic Charging Relays (ACR) and 7700
Remote Battery Switches (RBS) to manage the multiple Battery Bank system aboard the 355T.