Background Image
Table of Contents Table of Contents
Previous Page  32 / 148 Next Page
Information
Show Menu
Previous Page 32 / 148 Next Page
Page Background

B AT T E R Y M A N A G E M E N T

32

Specifications subject to change. See bluesea.com for current information.

Related Products

Features

Magnetic Latching (ML) relay draws very low current in the ON state

Start Isolation (SI) can be configured for temporary isolation of House loads from

Engine circuit during engine cranking to protect sensitive electronics

Engine Isolation (EI) can be configured for isolation of two engines while both are

running to protect engine electronics and maximize alternator output

Manual override knob provides an added level of safety allowing control with

or without power and offering LOCKED OFF capability for servicing

Senses charging on two battery banks

LED output to remotely indicate switch state - requires optional LED (p. 128) or

Remote Control Contura Switch with integrated LED (included in retail package)

3 ∕ 8"-16 tin-plated copper studs for maximum conductivity and corrosion resistance

7∕ 8" (22 mm) stud length accepts multiple cable terminals

One-piece stainless flange nuts ensure safe and secure connections

Label recesses for circuit identification

Silver alloy contacts provide high reliability for live switching

Retail packaging includes Remote Control Contura Switch 2146 (p. 69)

9160

Paralleling Link Bus

For paralleling ML-Remote Battery Switches

and Automatic Charging Relays

• Tin-plated copper for maximum conductivity and corrosion resistance

• 500A continuous rating

• Sold individually

ML-Series Automatic Charging Relays

500 Amp magnetic latching (bi-stable) relay automatically

combines batteries during charging and isolates batteries

when discharging and when starting engine

PN

Coil Volts

Cable End

Manual Control

Packaged

7620

12V DC

Stripped Wire

No

Retail

7620100B 12V DC

Deutsch DTM

No

Bulk

7622

12V DC

Stripped Wire

Yes

Retail

7622100B 12V DC

Deutsch DTM

Yes

Bulk

7621

24V DC

Stripped Wire

No

Retail

7621100B 24V DC

Deutsch DTM

No

Bulk

7623

24V DC

Stripped Wire

Yes

Retail

7623100B 24V DC

Deutsch DTM

Yes

Bulk

9160

Paralleling Link Bus

Retail

Specifications

ML-Coil Function

Bi-Stable

Amperage Operating Current

see table on page 34

Switching Cycles

100,000 Cycles

Live Current Switching

300A @ 12V DC—10,000 Cycles

Relay Contact Position

12V DC

24V DC

Combine (30 sec.)

13.5V DC

27.0V DC

(2 min.)

13.0V DC

26.0V DC

Open (10 sec.)

12.35V DC

24.7V DC

(30 sec.)

12.75V DC

25.5V DC

Over Voltage Lockout

16.2V DC

32.4V DC

Under Voltage Lockout

9.6V DC

19.2V DC

Under Voltage Recovery

10.0V DC

20.0V DC

Regulatory

E

marked, Meets ISO 8846 and SAE J1171 external ignition protection requirements

IP66—protected against powerful water jets (see inside back cover)

2146 Remote Control

Contura Switch

Action:

ON-OFF-ON

Included in retail package

Wire Color Circuit Function

Red

Remote

Black

Ground

Yellow LED Output

Brown

SI/EI #1

Green

SI/EI #2

Orange

SI/EI #3

Scan for

additional

product

information

7620

Deutsch DTM Cable End

provided on bulk units.

Other connector plugs

are available for high

volume OEM applications

Paralleling Link Bus

p. 32

ML-Series

Remote Battery Switches

p. 32

Battery Management

Panels

p. 69

Remote Control

Contura Switches

p. 69

7622

Wire Size

Cranking

10 sec.

Cranking

1 min.

Intermittent

5 min.

Continuous

(UL 1107)

2/0 AWG (70 mm²)

2,000A

750A

400A

225A

4/0 AWG (120 mm²)

2,200A

750A

400A

300A

2x 4/0 AWG (2x 120 mm²)

2,500A

1,100A

700A

500A

Wire Size and Current Ratings

MRBF® Terminal

Fuse Blocks

p. 46

Wire Harness

Connections