B AT T E R Y M A N A G E M E N T
Selection Chart
Choose the right Automatic Charging Relay for your application
P R E S E T A C R S E T T I N G S
Combine Voltage
- Charge present and loads do not exceed charge input
- Voltage of either battery is
≥
13.0V for 2 min.
- Relay will close, combining batteries
- Combined batteries share charge
P R O D U C T F E A T U R E S
Manual Override
Manual override knob provides
an added level of safely allowing
manual control of ON-OFF
7601
7611
7610
7620
7622
ACR
ACR
ACR
ACR
ACR
ACR
ACR
ACR
≥
13.0V
for 2 min.
Start
Auxiliary
Start
Auxiliary
Start
Auxiliary
Start
Auxiliary
Start
Auxiliary
Start
Auxiliary
Eng. 1 Start
Auxiliary
Eng. 2 Start
≤
12.75V
for 30 sec.
≤
12.75V
for 30 sec.
≥
13.0V
for 2 min.
≤
9.5V
≤
12.25V
for 30 sec.
≤
12.25V
for 30 sec.
1
Select an ACR that has a
CONTINUOUS
rating
above the maximum alternator output rating and
an
INTERMITTENT
rating that is above the largest
load on the auxiliary battery.
2
Review the
PRESET ACR SETTINGS
3
Select the ACR with the desired
PRODUCT FEATURES
65A
120A 120A 500A 500A
≥
13.0V
for 2 min.
Open Voltage
- No charge present or loads exceed charge input
- Combine voltage is
≤
12.75V for 30 sec.
- Relay will open, isolating batteries
- Isolated batteries do not share charge
Under Voltage Lockout
- Charge may or may not be present
- Voltage of either battery is
≤
9.5V (ML-ACR 9.6V)
- Relay will not close even with charge on other
battery, protecting ACR and wiring from high
surge current
- Isolated batteries do not share charge
Auxiliary Battery Priority
(0ptional)
Condition: Engine running
- Open voltage is lowered to 12.25V from 12.75V
- Relay remains closed longer, combining batteries,
to allow use of auxiliary loads for a longer period
of time
Start Isolation
(0ptional)
Condition: Engine starting
- Relay is open, isolating batteries
- Batteries are isolated to protect sensitive
electronics from voltage sags and spikes
Start Assist
Condition: Engine starting – (Press Contura Switch)
- Relay is closed, combining batteries
- Batteries are combined to share power in the
event of a low start battery
Engine Isolation
Condition: Two engines are running
- One relay is open and one relay is closed
- Engine 1 Start and Engine 2 Start batteries are
isolated to protect engine electronics
- If requested by engine manufacturer
Step
Step
PN
CONTINUOUS
Step
INTERMITTENT
115A 210A 210A 700A 700A