Specifications subject to change. See bluesea.com for current information.

B AT T E R Y M A N A G E M E N T

Selection Chart

Choose the right Automatic Charging Relay for your application

P R E S E T A C R S E T T I N G S

Combine Voltage

- Charge present and loads do not exceed charge input

- Voltage of either battery is

13.0V for 2 min.

- Relay will close, combining batteries

- Combined batteries share charge

P R O D U C T F E A T U R E S

Manual Override

Manual override knob provides

an added level of safely allowing

manual control of ON-OFF

7601

7611

7610

7620

7622

ACR

ACR

ACR

ACR

ACR

ACR

ACR

ACR

13.0V

for 2 min.

Start

Auxiliary

Start

Auxiliary

Start

Auxiliary

Start

Auxiliary

Start

Auxiliary

Start

Auxiliary

Eng. 1 Start

Auxiliary

Eng. 2 Start

12.75V

for 30 sec.

12.75V

for 30 sec.

13.0V

for 2 min.

9.5V

12.25V

for 30 sec.

12.25V

for 30 sec.

1

Select an ACR that has a

CONTINUOUS

rating

above the maximum alternator output rating and

an

INTERMITTENT

rating that is above the largest

load on the auxiliary battery.

2

Review the

PRESET ACR SETTINGS

3

Select the ACR with the desired

PRODUCT FEATURES

65A

120A 120A 500A 500A

13.0V

for 2 min.

Open Voltage

- No charge present or loads exceed charge input

- Combine voltage is

12.75V for 30 sec.

- Relay will open, isolating batteries

- Isolated batteries do not share charge

Under Voltage Lockout

- Charge may or may not be present

- Voltage of either battery is

9.5V (ML-ACR 9.6V)

- Relay will not close even with charge on other

battery, protecting ACR and wiring from high

surge current

- Isolated batteries do not share charge

Auxiliary Battery Priority

(0ptional)

Condition: Engine running

- Open voltage is lowered to 12.25V from 12.75V

- Relay remains closed longer, combining batteries,

to allow use of auxiliary loads for a longer period

of time

Start Isolation

(0ptional)

Condition: Engine starting

- Relay is open, isolating batteries

- Batteries are isolated to protect sensitive

electronics from voltage sags and spikes

Start Assist

Condition: Engine starting – (Press Contura Switch)

- Relay is closed, combining batteries

- Batteries are combined to share power in the

event of a low start battery

Engine Isolation

Condition: Two engines are running

- One relay is open and one relay is closed

- Engine 1 Start and Engine 2 Start batteries are

isolated to protect engine electronics

- If requested by engine manufacturer

Step

Step

PN

CONTINUOUS

Step

INTERMITTENT

115A 210A 210A 700A 700A