P OW E R C O N V E R S I O N

The P12 Battery Charger is a four stage, three output, dry mount

device designed for use in harsh environments where reliability, ease

of use, and high performance are of primary importance. Backed by

a 5-year warranty and technical phone support, the P12 Battery

Charger is designed, assembled, and tested at Blue Sea Systems’

company headquarters in Bellingham, Washington. The P12 Battery

Charger was designed to meet these three core company philosophies:

1. Reliability

Rugged, finned aluminum case

Universal line voltage 90–265V AC, 50/60 Hz

PreFloat

stage prevents over charging by allowing each battery to

end absorption stage individually

Power factor corrected for efficient use of AC

2. Ease of use

Intuitive diagnostic screens

User selectable charge profiles for Lead Acid, Gel, AGM, TPPL, and

other battery types

Provides charging for up to three battery banks

Large, bright display

Multi-language: English, French, German, Italian, Spanish

Charge coordination with Blue Sea Systems Automatic Charging

Relays (ACR) controls ACR state ensuring proper float stage for each battery

3. Support and Safety

Factory technical support

5 year warranty

Ignition protected

AC over and under voltage shut down and automatic restart

Over and under battery temperature protection

DC over voltage and reverse polarity protection

Surge and short circuit protection

P12 Battery Chargers

PN

Description

Volts

7521

25A Battery Charger

12V DC

7522

40A Battery Charger

12V DC

Scan for

additional

product

information

Related Products

Easily accessed, robust terminations designed for

maximum safety

SI-ACR

p. 30

ML-Series

Automatic Charging Relays

p. 32

P12 Battery Charger

LED Remote

p. 11

7.80" (198mm)

TOP MOUNTING

SCREW CENTERS

Ø0.3" (6.6mm)

CLEARANCE FOR:

M6,1/4",or #12

MOUNTING

HARDWARE

11.18"

(284mm)

MOUNTING

SCREW

CENTERS

13.00"

(330.6mm)

7.40" (188mm)

BOTTOM MOUNTING

SCREW CENTERS

8.46"

(215mm)

FOR DRIP PROOF

PERFORMANCE,CHARGER

MUST BE MOUNTED

VERTICALLYAS SHOWN

3.66"

(93mm)

Specifications

7521

7522

Total Output Current

25A

40A

Input AC Current

4.5A @ 100V AC

7.5A @ 100V AC

2.25A @ 200V AC

3.75A @ 200V AC

Recommended

160Ah Minimum,

220Ah Minimum,

Battery Bank Sizes*

Example: 2 x Group 27

Example: 2 x Group 31

330Ah Maximum,

440Ah Maximum,

Example: 3 x Group 31

Example: 4 x Group 31

Nominal Output Voltage 12V DC

12V DC

Output Connections

3 positive, 1 negative

3 positive, 1 negative

Universal AC Input Voltage 90V–265V AC

90V–265V AC

Input Frequency Range 45–65 Hz

45–65 Hz

Typical Float Voltage

13.5V DC

13.5V DC

Maximum Available Voltage 16.0V DC

16.0V DC

Output Voltage Accuracy 0.05V DC

0.05V DC

Operating Temperature

20°C (

4°F) to 70°C (158°F)

20°C (

4°F) to 70°C (158°F)

Storage Temperature

−30°C (−22°F) to 80°C (176°F) −30°C (−22°F) to 80°C (176°F)

Warranty

5 Year

5 Year

Battery Types**

Flooded, Gel, AGM, TPPL

Flooded, Gel, AGM, TPPL

* Battery bank sizes are recommended for optimal charging efficiency-see bluesea.com/P12 for details.

** Consult battery manufacturer specifications for other battery types to avoid damage.

Do not mix battery chemistries.

Regulatory

Designed and constructed for compliance to UL-1236 Marine, CSA 22.2 No. 107.2,

and ABYC A-31 standards. Ignition Protection per ISO 8846, and SAE J1171.

Meets FCC Part 15, Class B requirements.