137

A P P E N D I X

3 Battery - 2 Engine

4 Battery - 2 Engine - 1 Generator

Can isolate any battery source from any batteries.

3 Selector Battery Switches

2 Automatic Charging Relays

Can parallel batteries for extra starting power.

3 Dual Circuit Plus™ Battery Switches

3 Automatic Charging Relays

Can isolate any battery source from any batteries.

4 Selector Battery Switches

3 Automatic Charging Relays

Normal - Set all switches to position 1

Parallel - Set all switches to position 1+2

Isolate - Set Load switch to Position 2 and

Source Switch to position 1+2

Normal - Set all switches to position 1

Parallel - Set all switches to position 1+2

Isolate - Set Load switch to Position 2 and

Source Switch to position 1+2

Can parallel batteries for extra starting power.

2 Dual Circuit Plus™ Battery Switches

2 Automatic Charging Relays

ACR

ACR

Start

House

Start

House

Engine

Engine

ACR

ACR

ACR

House

Generator

Start

Engine

Engine

Generator

House

Start

ACR

ACR

ACR

House

Generator

Start

Engine

Engine

Generator

Start

House

ACR

ACR

Start

House

Start

House

Engine

Engine

DC Positive

LEGEND

DC Ground