137
A P P E N D I X
3 Battery - 2 Engine
4 Battery - 2 Engine - 1 Generator
Can isolate any battery source from any batteries.
3 Selector Battery Switches
2 Automatic Charging Relays
Can parallel batteries for extra starting power.
3 Dual Circuit Plus™ Battery Switches
3 Automatic Charging Relays
Can isolate any battery source from any batteries.
4 Selector Battery Switches
3 Automatic Charging Relays
Normal - Set all switches to position 1
Parallel - Set all switches to position 1+2
Isolate - Set Load switch to Position 2 and
Source Switch to position 1+2
Normal - Set all switches to position 1
Parallel - Set all switches to position 1+2
Isolate - Set Load switch to Position 2 and
Source Switch to position 1+2
Can parallel batteries for extra starting power.
2 Dual Circuit Plus™ Battery Switches
2 Automatic Charging Relays
ACR
ACR
Start
House
Start
House
Engine
Engine
ACR
ACR
ACR
House
Generator
Start
Engine
Engine
Generator
House
Start
ACR
ACR
ACR
House
Generator
Start
Engine
Engine
Generator
Start
House
ACR
ACR
Start
House
Start
House
Engine
Engine
DC Positive
LEGEND
DC Ground