B AT T E R Y M A N A G E M E N T

18

Specifications subject to change. See bluesea.com for current information.

Rear

Front

9003

e,

9004

e

*

e

-Series Battery Switches

350 Amps continuous rating for inboard gasoline

or diesel engines

Features

Tin-plated copper studs for maximum conductivity and corrosion resistance

Accepts up to 4/0 AWG (120 mm²) battery cables

Studs accept 3 ∕ 8" (M10) ring terminals

7∕ 8" (22 mm) stud length accepts multiple cable terminals

Blue Sea Systems one-piece terminal stud design never loosens over time

One-piece stainless flange nuts ensure safe and secure connections

Fits most Perko and Guest low amperage battery switch hole patterns

Case design allows surface or rear mounting options

Tactile indicator conveys knob position by feel

Icon Circuit Identification Label Kit available 7902 - sold separately (p. 129)

Specifications

9003 9001 , 5510

9004 9002 5511

11001

Cranking Rating:

10 sec.

2,000A 2,000A 1,000A

per circuit

Cranking Rating:

1 min.

1,000A 1,000A 750A

per circuit

Intermittent Rating:

5 min.

600A 600A 525A

per circuit

Continuous Rating

350A 350A 350A

per circuit

Voltage Max. Operating

48V DC 32V DC 32V DC

Regulatory

E

marked, ISO 8846,UL Listed - UL 1107 electric power switches

Meets American Boat and Yacht Council (ABYC) requirements

Meets UL 1500 and SAE J1171 external ignition protection requirements

IP66—protected against powerful water jets (see inside back cover)

Single Circuit ON-OFF

Switches a single battery to

a single load group

9001

e,

9002

e

*

Selector 4 Position

Switches isolated battery banks

to all loads or combines battery

banks to all loads

11001 *

Selector 3 Position

Switches isolated battery banks

to all loads

* Includes Alternator Field Disconnect

(AFD) which protects the diodes in the

alternator in the event of the switch

being switched to the OFF position while

the engine is running. If the AFD is not

used to protect the alternator, an LED

can be connected to the AFD terminals

to indicate when the battery switch is in

any position but OFF.

WARNING

The positive and negative conductors

should not be attached to the same

battery switch. The only exceptions are

the Dual Circuit Battery Switches, PN

6010 and 5510

e

. Since these models

have electrically isolated circuits and do

not include a combine feature, they can

provide disconnect to the positive and

negative conductors simultaneously.

For the full list of specifications, see pages 20–21

5510

e

PATENTED

Dual Circuit

Simultaneously switches two

isolated battery banks or circuits.

May be used to switch the positive

and negative conductors for

required applications.

5511

e

PATENTED

Dual Circuit Plus

Simultaneously switches

two isolated battery banks or

combines battery banks to

all loads. CAN NOT be used to

switch positive and negative

conductors because of the

combine feature.

Circuit Identification Label Kit

p. 129

SI-ACR

p. 30

3.00"

76.20mm

3.85"

97.79mm

3.00"

76.20mm

3.85"

97.79mm

REAR

PANEL

MOUNT IN

3-5

/

8"

92mm

Ø HOLE

1.59"

40.39mm

3.097"

78.67mm

0.77"

19.56mm

Related Products

For the complete list

of battery switch operational

diagrams, see pages 136–137

Add-A-Battery

p. 31

INVERTER

CHASSIS

GENERATOR

PARALLEL

ENGINE1

BATTERY1 BATTERY2 BATTERY3

ENGINE

PORT

ENGINE

STARBOARD

ENGINE

MID

HOUSE

BOW

THRUSTER

WINDLASS

INVERTER GROUND

ENGINE4

ENGINE3

ENGINE2

Mounting Options

PN

Description

AFD*

5510

e

Dual Circuit™

-

5511

e

Dual Circuit Plus™

-

9001

e

Selector 4 Position

-

9002

e

Selector 4 Position

Yes

9003

e

Single Circuit ON-OFF

-

9004

e

Single Circuit ON-OFF

Yes

11001

Selector 3 Position

Yes