C I R C U I T P R O T E C T I O N
58
Specifications subject to change. See bluesea.com for current information.
A-Series Toggle Circuit Breakers
Combines switching and circuit protection into a single device
UL 1077 - UL/CSA
(US/Canada)
EN60934 - TUV
(Europe)
Poles
Volts
Amps
Interrupt
Interrupt
1 Pole
65V DC
5–50A
7,500A
-
120V AC
5–50A
3,000A
-
250V AC
5–50A
3,000A
1,500A
65V DC
10–50A
7,500A
-
2 Pole
120V AC
10–50A
3,000A
-
120/240V AC 10–50A
3,000A
-
250V AC
10–50A
3,000A
1,500A
2.000"
50.80mm
1.050"
26.67mm
0.170"
4.32mm
OVERALL DEPTH
2.00" 50.80mm
0.750"
19.05mm
0.630" DIA.
Ø16.00mm
0.156" DIA.
Ø3.96mm
0.750" 19.05mm
TYP PER POLE
1.660"
42.16mm
1.050"
26.67mm
7200
7202
8072
PN Color
DC Amps AC Amps
7200 Black
5A DC 5A AC
7201 Red
5A DC 5A AC
7202 White
5A DC 5A AC
7347 Black
8A DC 8A AC
7299 White
8A DC 8A AC
7204 Black
10A DC 10A AC
7205 Red
10A DC 10A AC
7206 White
10A DC 10A AC
7208 Black
15A DC 15A AC
7209 Red
15A DC 15A AC
7210 White
15A DC 15A AC
7212 Black
20A DC 20A AC
7213 Red
20A DC 20A AC
7214 White
20A DC 20A AC
7216 Black
25A DC 25A AC
7217 Red
25A DC 25A AC
7218 White
25A DC 25A AC
7220 Black
30A DC 30A AC
7221 Red
30A DC 30A AC
7222 White
30A DC 30A AC
7224 Black
40A DC 40A AC
7225 Red
40A DC 40A AC
7226 White
40A DC 40A AC
7228 Black
50A DC 50A AC
7229 Red
50A DC 50A AC
7230 White
50A DC 50A AC
7233
2.000"
50.80mm 1.050"
26.67mm
0.170"
4.32mm
OVERALL DEPTH
2.00" 50.80mm
0.750"
19.05mm
1.500"
38.10mm
Features
•
The standard circuit breaker for Blue Sea Systems Traditional Metal
Power Distribution Panels
•
Single pole is frequently used for AC or DC Branch circuit protection
•
Double pole is typically used for AC Main circuit protection
•
Trip Free— cannot be held closed after trip
Specifications
Interrupting Capacity
See Interrupting Capacity Table
Voltage Max. Operating
65V DC / 250V AC
Amperage Trip Reference
See table
Temperature Min. Operating
-40°C
Temperature Max. Operating
85°C
Switching Cycles
10,000 @ rated amps and volts
Type
Magnetic Hydraulic—Trip free
Terminal Screw
#10-32 Stainless Steel
Terminal Screw Torque
14–15 in-lb Recommended
Trip Time Delay
See
www.bluesea.comMounting Screw
#6-32 Stainless Steel
(included)
Mounting Screw Torque
6–8 in-lb Recommended
Regulatory
E
marked, TUV certified, CSA certified, UL 1077 recognized
PN
Color
DC Amps AC Amps
7232 Black
10A DC 10A AC
7233 White 10A DC 10A AC
7234 Black
15A DC 15A AC
7235 White 15A DC 15A AC
7348 Black
16A DC 16A AC
7294 White 16A DC 16A AC
7236 Black
20A DC 20A AC
7260 White 20A DC 20A AC
7237 Black
30A DC 30A AC
7238 White 30A DC 30A AC
7349 Black
32A DC 32A AC
7295 White 32A DC 32A AC
7239 Black
40A DC 40A AC
7240 White 40A DC 40A AC
7241 Black
50A DC 50A AC
7242 White 50A DC 50A AC
8173
Cutout Dimensions
PN
Description
Width in (mm)
Height in (mm)
Depth in (mm)
3131 Circuit Breaker Enclosure
3.95 (100.36)
4.92 (124.91)
4.07 (103.40)
8072 Single pole mounting panel
2.63 (66.80)
3.75 (92.25)
0.125 (3.175)
8173 Double pole mounting panel
2.63 (66.80)
3.75 (92.25)
0.125 (3.175)
Interrupting Capacity Table (see ABYC Requirements page 138)
Circuit Breaker Mounting Options
•
3131 enclosure, strain reliefs included for secure installation
of circuit breakers
•
3131 enclosure, accepts A-Series Toggle and A and C-Series Flat Rocker
Circuit Breakers, LEDs (p. 128), and Square Format Labels (p. 129)
for custom configurations
•
8072 and 8173 panels, accept A-Series Toggle Circuit Breakers,
Large Format Labels (p. 129) and LEDs (p. 128)
3131
1.640"
41.66mm
0.130"
3.30mm
0.690"
17.50mm
2.032"
51.61mm
1.560"
39.62mm
Related Products
360 Panel System p. 90
Traditional Metal Panel p. 91
Single Pole Circuit Breakers
Double Pole Circuit Breakers