C I R C U I T P R O T E C T I O N

63

Specifications subject to change. See bluesea.com for current information.

Related Products

Residual Current Circuit Breakers

GFCI Branch and ELCI Main

Residual Current Devices (RCDs) respond to leakage of electrical current outside of the

intended circuit path. When the RCD function is combined with a circuit breaker for over

current protection, the device is often referred to as an RCBO. In the USA, a device that trips

on leakages of nominally 5mA and meets certain standards is called a Ground Fault Circuit

Interrupter (GFCI). A device meeting the same standards but with a trip level of 30mA is

called an Equipment Leakage Circuit Interrupter (ELCI). The devices below provide GFCI

Branch or ELCI Main functions and circuit protection in panel mounted breakers.

Features

Trips on short circuit, overload, or leakage to ground

For installation in a power distribution panel

GFCI Branch - Provides overcurrent and leakage protection per ABYC E-11

for head, galley, machinery and weather deck receptacles

ELCI Main - Provides overcurrent and leakage protection per ABYC E-11

for whole boat shore power protection

Specifications

Interrupting Capacity

5,000 Amps

Temperature Min. Operating

-35°C

Temperature Max. Operating

66°C

Switching Cycles

10,000 @ rated amperage and voltage

Type

Magnetic Hydraulic—Trip free

Mounting Screw

#6-32 Stainless Steel

Mounting Screw Torque

6–8 in-lb Recommended

Regulatory

3100— UL 1077, UL 943 Class A

3103, 3104, 3102100, 3106100, 3091, 3092, 3093— UL 1077, UL 943 Class A, UL 1500

AC and AC/DC Circuit Breakers Only

E

marked

3103, 3091, 3092, 3093

3104

3106100

3100

3102100

* 230V AC, Typical of Europe

† 240V AC, For isolation transformer applications

PN Description

Frame

Series

Nominal Voltage

Actuator

Ignition

Protected

Poles

AC Amperage

Leakage

Trip

Amps

MAIN BRANCH

3100 GFCI Branch A-Series

120V AC per pole

Flat Rocker

-

1

-

15A 5mA

3102100 ELCI Main A-Series

120V AC per pole

Flat Rocker

Yes

2 30A

-

30mA

3103 ELCI Main C-Series

120V AC per pole

Flat Rocker

Yes

2 50A

-

30mA

3104 ELCI Main C-Series 120/240V AC per pole Flat Rocker

Yes

3 50A

-

30mA

3106100 ELCI Main A-Series

120V AC per pole White Toggle

Yes

2 30A

-

30mA

3091 ELCI Main C-Series 230V AC per pole* Flat Rocker

Yes

2 16A

-

30mA

3092 ELCI Main C-Series 230V AC per pole* Flat Rocker

Yes

2 32A

-

30mA

3093 ELCI Main C-Series 240V AC per pole † Flat Rocker

Yes

2 50A

-

30mA