C I R C U I T P R O T E C T I O N

61

Specifications subject to change. See bluesea.com for current information.

Cutout Dimensions

0.200"

5.08mm

0.750"

19.05mm

1.260"

32.00mm

1.660"

42.16mm

0.750" 19.05mm

TYP PER POLE

0.156" DIA.

Ø3.96mm

2.500"

63.50mm

OVERALL DEPTH

2.84" (72.14)

2.250"

57.15mm 1.500"

38.10mm

0.750"

19.05mm

1.245"

31.62mm

UL 1077 - UL/CSA

(US/Canada)

EN60934 - TUV

(Europe)

Poles

Volts

Amps

Interrupt

Interrupt

1 Pole

32V DC

5–100A

5,000A

-

120V AC

5–100A

3,000A

-

240V AC

5–50A

3,500A

-

2 and 3

Pole

48V DC 150–300A

5,000A

-

48V DC 150–200A

-

5,000A

120/240V AC

30–100A

5,000A

-

240V AC

30–100A

-

5,000A

Interrupting Capacity Table (see ABYC Requirements page 138)

C-Series Rocker Circuit Breakers

Combines switching and circuit protection into a single device

AC Features

Used for 120/240 Volt AC circuit protection

Double pole can be used as AC Main circuit breaker to switch hot

and neutral or two hots in 120/240 Volt AC Branch applications

Triple pole can be used as 120/240 Volt AC Main circuit breaker

to switch both lines (hots) and neutral

Double and triple pole circuit breakers will trip all poles if any

one pole trips

DC Features

White actuator indicates OFF position

Large frame provides stud termination for 5–300 Amp loads

Flat rocker actuator is flush in the ON position, reducing the risk of

accidental switching

Provides overcurrent protection for inverters, bow thrusters, and windlasses

Trip Free—cannot be held closed after trip

Specifications

Interrupting Capacity

See Interrupt Capacity Table

Voltage Max. Operating

See Interrupt Capacity Table

Amperage Trip Reference

See table

Temperature Min. Operating

-40°C

Temperature Max. Operating

85°C

Switching Cycles

10,000 @ rated amperage and voltage

Type

Magnetic Hydraulic—Trip free

Terminal Stud

1 ∕4"-20 Tin-Plated Brass

Terminal Stud Torque

35 in-lb max.

Trip Time Delay

See

www.bluesea.com

Mounting Screw

#6-32 Stainless Steel (included)

Mounting Screw Torque

6–8 in-lb Recommended

Regulatory

Single-pole circuit breakers only

E

marked, meet SAE J1171, UL 1500

and ISO 8846 external ignition protection requirements, CSA certified,

and UL 1077 recognized

AC Circuit breakers only

—TUV certified, CSA certified, and UL 1077 recognized

AC and AC/DC Circuit breakers only

E

marked

OVERALL DEPTH

2.84" (72.14)

0.750"

19.05mm

1.245"

31.62mm

2.550"

64.77mm

7540

7475

7554

7580

7568

DC AC

DC

AC

*

Paralleled poles have 5/16" stud on bus

Related Product

360 Panel System 1168 p. 90

PN DC Amps AC Amps

Rocker Actuator

7540 5A DC 5A AC

Flat

7541 10A DC 10A AC

Flat

7542 15A DC 15A AC

Flat

7543 20A DC 20A AC

Flat

7545 30A DC 30A AC

Flat

7546 50A DC 50A AC

Flat

7547 60A DC 60A AC

Flat

7548 80A DC 80A AC

Flat

7549 100A DC 100A AC

Flat

PN DC Amps AC Amps

Rocker Actuator

7560

-

30A AC

Flat

7580

-

30A AC

Raised

7561

-

50A AC

Flat

7581

-

50A AC

Raised

7582

-

60A AC

Raised

7563

-

80A AC

Flat

7583

-

80A AC

Raised

7564

-

100A AC

Flat

7584

-

100A AC

Raised

7475 * 150A DC

-

Flat

7476 * 200A DC

-

Flat

PN DC Amps AC Amps

Rocker Actuator

7565

-

50A AC

Flat

7585

-

50A AC

Raised

7568

-

100A AC

Flat

7588

-

100A AC

Raised

7477 * 250A DC

-

Flat

7554 * 300A DC

-

Flat

Single Pole Circuit Breakers

Double Pole Circuit Breakers

Triple Pole Circuit Breakers