C I R C U I T P R O T E C T I O N
61
Specifications subject to change. See bluesea.com for current information.
Cutout Dimensions
0.200"
5.08mm
0.750"
19.05mm
1.260"
32.00mm
1.660"
42.16mm
0.750" 19.05mm
TYP PER POLE
0.156" DIA.
Ø3.96mm
2.500"
63.50mm
OVERALL DEPTH
2.84" (72.14)
2.250"
57.15mm 1.500"
38.10mm
0.750"
19.05mm
1.245"
31.62mm
UL 1077 - UL/CSA
(US/Canada)
EN60934 - TUV
(Europe)
Poles
Volts
Amps
Interrupt
Interrupt
1 Pole
32V DC
5–100A
5,000A
-
120V AC
5–100A
3,000A
-
240V AC
5–50A
3,500A
-
2 and 3
Pole
48V DC 150–300A
5,000A
-
48V DC 150–200A
-
5,000A
120/240V AC
30–100A
5,000A
-
240V AC
30–100A
-
5,000A
Interrupting Capacity Table (see ABYC Requirements page 138)
C-Series Rocker Circuit Breakers
Combines switching and circuit protection into a single device
AC Features
•
Used for 120/240 Volt AC circuit protection
•
Double pole can be used as AC Main circuit breaker to switch hot
and neutral or two hots in 120/240 Volt AC Branch applications
•
Triple pole can be used as 120/240 Volt AC Main circuit breaker
to switch both lines (hots) and neutral
•
Double and triple pole circuit breakers will trip all poles if any
one pole trips
DC Features
•
White actuator indicates OFF position
•
Large frame provides stud termination for 5–300 Amp loads
•
Flat rocker actuator is flush in the ON position, reducing the risk of
accidental switching
•
Provides overcurrent protection for inverters, bow thrusters, and windlasses
•
Trip Free—cannot be held closed after trip
Specifications
Interrupting Capacity
See Interrupt Capacity Table
Voltage Max. Operating
See Interrupt Capacity Table
Amperage Trip Reference
See table
Temperature Min. Operating
-40°C
Temperature Max. Operating
85°C
Switching Cycles
10,000 @ rated amperage and voltage
Type
Magnetic Hydraulic—Trip free
Terminal Stud
1 ∕4"-20 Tin-Plated Brass
Terminal Stud Torque
35 in-lb max.
Trip Time Delay
See
www.bluesea.comMounting Screw
#6-32 Stainless Steel (included)
Mounting Screw Torque
6–8 in-lb Recommended
Regulatory
Single-pole circuit breakers only
—
E
marked, meet SAE J1171, UL 1500
and ISO 8846 external ignition protection requirements, CSA certified,
and UL 1077 recognized
AC Circuit breakers only
—TUV certified, CSA certified, and UL 1077 recognized
AC and AC/DC Circuit breakers only
—
E
marked
OVERALL DEPTH
2.84" (72.14)
0.750"
19.05mm
1.245"
31.62mm
2.550"
64.77mm
7540
7475
7554
7580
7568
DC AC
DC
AC
*
Paralleled poles have 5/16" stud on bus
Related Product
360 Panel System 1168 p. 90
PN DC Amps AC Amps
Rocker Actuator
7540 5A DC 5A AC
Flat
7541 10A DC 10A AC
Flat
7542 15A DC 15A AC
Flat
7543 20A DC 20A AC
Flat
7545 30A DC 30A AC
Flat
7546 50A DC 50A AC
Flat
7547 60A DC 60A AC
Flat
7548 80A DC 80A AC
Flat
7549 100A DC 100A AC
Flat
PN DC Amps AC Amps
Rocker Actuator
7560
-
30A AC
Flat
7580
-
30A AC
Raised
7561
-
50A AC
Flat
7581
-
50A AC
Raised
7582
-
60A AC
Raised
7563
-
80A AC
Flat
7583
-
80A AC
Raised
7564
-
100A AC
Flat
7584
-
100A AC
Raised
7475 * 150A DC
-
Flat
7476 * 200A DC
-
Flat
PN DC Amps AC Amps
Rocker Actuator
7565
-
50A AC
Flat
7585
-
50A AC
Raised
7568
-
100A AC
Flat
7588
-
100A AC
Raised
7477 * 250A DC
-
Flat
7554 * 300A DC
-
Flat
Single Pole Circuit Breakers
Double Pole Circuit Breakers
Triple Pole Circuit Breakers