C I R C U I T P R O T E C T I O N
64
Specifications subject to change. See bluesea.com for current information.
Related Products
PN
Description
Installed Circuit Breakers
Glands Included
3113 6 Blank Circuit Positions
-
-
3116 ELCI Main + 3 Blank Circuit Positions
1 ELCI Main 120V, 30A, 30mA (3102)
2 x 3124
3 x 3125
3117 120V AC ELCI 30A Dual
2 ELCI Main 120V 30A, 30mA (3102)
2 x 3124
4 x 3125
3118 ELCI Main + 2 Blank Circuit Positions
1 ELCI Main 120V 50A, 30mA (3103)
2 x 3124
1 x 3125
2 x 3126
3119 ELCI Main + 1 Blank Circuit Position
1 ELCI Main 120/240V, 50A, 30mA (3104)
2 x 3124
1 x 3125
2 x 3126
3120 ELCI Main + 2 Blank Circuit Positions
1 ELCI Main 240V, 50A, 30mA (3093)
2 x 3124
1 x 3125
2 x 3126
3124 Small Gland PG7, #14 to #10 Single Wire
3125 Medium Gland PG16, #14 to #10, 3 Conductor
3126 Large Gland PG29, #6 Cable, 4 Conductor
SMS Surface Mount System
Panel enclosure for ELCI Main circuit breakers and other
large frame devices. Meets ABYC E-11 when used with an
ELCI Main circuit breaker and mounted within 10 feet of
the shore power inlet
Features
•
Models available with ELCI Main circuit breakers for 120V 30A,
120V 50A, and 120/240V 50A
•
Blank apertures for custom breaker loading
•
Clear cover allows easy view of circuit breaker status
•
Blank circuit positions accommodate Carling Technologies™
A and C Series Flat Rocker and ELCI Main circuit breakers
•
Stainless steel mounting hardware included
•
Includes waterproof glands (except 3113)
•
Green LEDs for backlighting and ON indication (except 3113)
Specifications
Enclosure Size
6.0" x 6.0" x 4.0"
152 mm x 152 mm x 102 mm
Base Material
Glass Filled Polycarbonate
Exterior Overall Dimensions 7.6" x 7.4" x 4.7"
192 mm x 188 mm x 120 mm
Temperature Range
-40°C to 85°C
Cover Screws and Hardware 10-32 stainless steel
Mounting Hardware
Ø 1/4", #12, (6 mm)
Regulatory
IP66—Protected against powerful water jets when cover is latched
(see inside back cover)
Flammability rating—Per UL 508
Toxicity— Non-toxic, halogen free, RoHS compliant
UL Listed and NEMA 4X rated, NEMA Type 4, 4X, 6, 6P, 12, and 13
See page 138 for ABYC Interrupting Capacity Requirements.
* SMS panel enclosures are pre-assembled and ready for wire connections. Customers
must select wire and entry or exit locations, drill holes, and install the appropriate glands.
3120
Circuit Breaker Enclosure
p. 58
A-Series Toggle and Rocker
Circuit Breakers p. 58-59
ELCI Circuit Breakers
p. 63
C-Seris Rocker Circuit Breakers
p. 60-61
4.96"
126.1mm
7.65"
194.2mm
8.13"
206.4mm
4.00"
101.6mm
MOUNTING HARDWARE
CLEARANCE FOR:
Ø1/4",#12,OR 6mm
6.65"
168.8mm
7.35"
186.8mm
TOP
BOTTOM
SIDE