Background Image
Table of Contents Table of Contents
Previous Page  59 / 148 Next Page
Information
Show Menu
Previous Page 59 / 148 Next Page
Page Background

C I R C U I T P R O T E C T I O N

59

Specifications subject to change. See bluesea.com for current information.

Features

White actuator indicates OFF position

Single pole is available in Flat Rocker and Restricted Off styles

Single pole is frequently used for AC or DC Branch circuit protection

Double pole is available in Flat Rocker and Raised Rocker styles

Double pole is typically used for AC Main circuit protection

Raised Rocker actuator style is used for AC source selection on the

360 Panel System

International ON and OFF symbols support vertical or horizontal mounting

Specifications

Interrupting Capacity

See Interrupting Capacity table below

Voltage Max. Operating

32V DC / 250V AC

Amperage Trip Reference

See table

Temperature Min. Operating

- 40°C

Temperature Max. Operating

85°C

Switching Cycles

10,000 @ rated amps and volts

Type

Magnetic Hydraulic—Trip free

Terminal Screw

#10-32 Stainless Steel

Terminal Screw Torque

14–15 in-lb Recommended

(load terminal is 30° angled)

Trip Time Delay

See

www.bluesea.com

Mounting Screw

#6-32 Stainless Steel (included)

Mounting Screw Torque

6–8 in-lb Recommended

Regulatory

E

marked, TUV certified, CSA certified, UL 1077 recognized

0.200"

5.08mm

0.156" DIA

Ø3.96mm

0.750" 19.05mm

TYP PER POLE

1.660"

42.16mm

0.750"

19.05mm

1.260"

32.00mm

1.239"

31.47mm

OVERALL DEPTH

2.40" 60.96mm

0.750"

19.05mm

1.660"

42.16mm

2.217"

56.31mm

Interrupting Capacity Table (see ABYC Requirements page 138)

UL 1077 - UL/CSA

(US/Canada)

EN60934 - TUV

(Europe)

Poles

Volts

Amps

Interrupt

Interrupt

1 Pole

32V DC

5–50A

5,000A

-

125V AC

5–50A

3,000A

-

250V AC

5–50A

1,500A

1,500A

2 Pole

32V DC

10–50A

5,000A

-

240V AC 10–50A

3,000A

-

240V AC 10–50A

3,000A

1,500A

1.245"

31.62mm

OVERALL DEPTH

2.40" 60.96mm

1.500"

38.10mm

2.310"

58.67mm

A-Series Rocker Circuit Breakers

Combines switching and circuit protection into a single device

Cutout Dimensions

7574

Raised Rocker

Standard circuit breaker for

AC Source Select panels in

the 360 Panel System

I

30A

7403

Flat Rocker

Standard circuit breaker used on

the 360 Panel System

(1200 Series)

Flat actuator resists accidental

switching by being flush in the

ON position

I

50

7425

Restricted-OFF Rocker

Actuator shows white in

the OFF position

Restricted OFF actuator can

only be switched to OFF by

insertion of small screwdriver

into slot

I

50

PN DC Amps AC Amps

Rocker Actuator

7400

5A DC

5A AC

Flat

7425

5A DC

5A AC

Restricted-OFF

7401

8A DC

8A AC

Flat

7402 10A DC 10A AC

Flat

7427 10A DC 10A AC

Restricted-OFF

7403 15A DC 15A AC

Flat

7428 15A DC 15A AC

Restricted-OFF

7404 20A DC 20A AC

Flat

7429 20A DC 20A AC

Restricted-OFF

7405 25A DC 25A AC

Flat

7430 25A DC 25A AC

Restricted-OFF

7406 30A DC 30A AC

Flat

7407 40A DC 40A AC

Flat

7408 50A DC 50A AC

Flat

7433 50A DC 50A AC

Restricted-OFF

Related Products

360 Panel System p. 90

PN DC Amps AC Amps

Rocker Actuator

7410 10A DC 10A AC

Flat

7411 15A DC 15A AC

Flat

7412 16A DC 16A AC

Flat

7413 20A DC 20A AC

Flat

7574 30A DC 30A AC

Raised

7414 30A DC 30A AC

Flat

7575 32A DC 32A AC

Raised

7415 32A DC 32A AC

Flat

7416 40A DC 40A AC

Flat

7577 50A DC 50A AC

Raised

7417 50A DC 50A AC

Flat

Single Pole Circuit Breakers

Double Pole Circuit Breakers