C I R C U I T P R O T E C T I O N
59
Specifications subject to change. See bluesea.com for current information.
Features
•
White actuator indicates OFF position
•
Single pole is available in Flat Rocker and Restricted Off styles
•
Single pole is frequently used for AC or DC Branch circuit protection
•
Double pole is available in Flat Rocker and Raised Rocker styles
•
Double pole is typically used for AC Main circuit protection
•
Raised Rocker actuator style is used for AC source selection on the
360 Panel System
•
International ON and OFF symbols support vertical or horizontal mounting
Specifications
Interrupting Capacity
See Interrupting Capacity table below
Voltage Max. Operating
32V DC / 250V AC
Amperage Trip Reference
See table
Temperature Min. Operating
- 40°C
Temperature Max. Operating
85°C
Switching Cycles
10,000 @ rated amps and volts
Type
Magnetic Hydraulic—Trip free
Terminal Screw
#10-32 Stainless Steel
Terminal Screw Torque
14–15 in-lb Recommended
(load terminal is 30° angled)
Trip Time Delay
See
www.bluesea.comMounting Screw
#6-32 Stainless Steel (included)
Mounting Screw Torque
6–8 in-lb Recommended
Regulatory
E
marked, TUV certified, CSA certified, UL 1077 recognized
0.200"
5.08mm
0.156" DIA
Ø3.96mm
0.750" 19.05mm
TYP PER POLE
1.660"
42.16mm
0.750"
19.05mm
1.260"
32.00mm
1.239"
31.47mm
OVERALL DEPTH
2.40" 60.96mm
0.750"
19.05mm
1.660"
42.16mm
2.217"
56.31mm
Interrupting Capacity Table (see ABYC Requirements page 138)
UL 1077 - UL/CSA
(US/Canada)
EN60934 - TUV
(Europe)
Poles
Volts
Amps
Interrupt
Interrupt
1 Pole
32V DC
5–50A
5,000A
-
125V AC
5–50A
3,000A
-
250V AC
5–50A
1,500A
1,500A
2 Pole
32V DC
10–50A
5,000A
-
240V AC 10–50A
3,000A
-
240V AC 10–50A
3,000A
1,500A
1.245"
31.62mm
OVERALL DEPTH
2.40" 60.96mm
1.500"
38.10mm
2.310"
58.67mm
A-Series Rocker Circuit Breakers
Combines switching and circuit protection into a single device
Cutout Dimensions
7574
Raised Rocker
•
Standard circuit breaker for
AC Source Select panels in
the 360 Panel System
I
30A
7403
Flat Rocker
•
Standard circuit breaker used on
the 360 Panel System
(1200 Series)
•
Flat actuator resists accidental
switching by being flush in the
ON position
I
50
7425
Restricted-OFF Rocker
•
Actuator shows white in
the OFF position
•
Restricted OFF actuator can
only be switched to OFF by
insertion of small screwdriver
into slot
I
50
PN DC Amps AC Amps
Rocker Actuator
7400
5A DC
5A AC
Flat
7425
5A DC
5A AC
Restricted-OFF
7401
8A DC
8A AC
Flat
7402 10A DC 10A AC
Flat
7427 10A DC 10A AC
Restricted-OFF
7403 15A DC 15A AC
Flat
7428 15A DC 15A AC
Restricted-OFF
7404 20A DC 20A AC
Flat
7429 20A DC 20A AC
Restricted-OFF
7405 25A DC 25A AC
Flat
7430 25A DC 25A AC
Restricted-OFF
7406 30A DC 30A AC
Flat
7407 40A DC 40A AC
Flat
7408 50A DC 50A AC
Flat
7433 50A DC 50A AC
Restricted-OFF
Related Products
360 Panel System p. 90
PN DC Amps AC Amps
Rocker Actuator
7410 10A DC 10A AC
Flat
7411 15A DC 15A AC
Flat
7412 16A DC 16A AC
Flat
7413 20A DC 20A AC
Flat
7574 30A DC 30A AC
Raised
7414 30A DC 30A AC
Flat
7575 32A DC 32A AC
Raised
7415 32A DC 32A AC
Flat
7416 40A DC 40A AC
Flat
7577 50A DC 50A AC
Raised
7417 50A DC 50A AC
Flat
Single Pole Circuit Breakers